Mô tả sản phẩm
Fluid sensors
Features
Pressure type | Gauge pressure |
Measuring range | 0 bar … 25 bar |
Process temperature | ?30 ?C … +100 ?C |
Output signal | 0 V … 10 V, 3-wire |
Pieces per package | 50 pieces |
Performance
Non-linearity | ? ? 0.5 % of span (best fit straight line, BFSL) |
Accuracy | ? ? 1.2 % of span (at room temperature) |
Response time | < 2 ms |
Measurement deviation of zero signal | ? ? 0.5 % of the span |
Temperature error | ? ? 1.5 % of the span |
Long-term drift/one-year stability | ? ? 0.3 % of span (per year) |
Rated temperature range | 0 ?C … +80 ?C |
Reference conditions | According to IEC 61298-1 |
Mechanics/electronics
Process connection | G ? A according to DIN 3852-E |
Seal | NBR |
Wetted parts | Stainless steel 316L, stainless steel 13-8 PH |
Pressure port | 3.5 mm Standard |
Housing material | Stainless steel 316L, PBT GF30 |
Enclosure rating | IP67, for round connector (according to IEC 60529) 1) |
Connection type | M12 round connector x 1, 4-pin |
Supply voltage | 14 V DC … 30 V DC 2) |
Maximum ohmic load RA | > QA, max / 1 mA [ohm] for current output signal |
Maximum power consumption | 5 mA |
Initialization time | 15 ms |
Protection class | III |
Isolation voltage | 750 V DC |
Overvoltage protection | 36 V DC |
Short-circuit protection | Output QA towards M |
Reverse polarity protection | L+ towards M |
CE-conformity | 2004/108/EC, EN 61326-1 emission (group 1, class B) and interference immunity (industrial application) and pressure equipment directive 97/23/EC |
RoHS certificate | ? |
Service life | Minimum 100 Mio. life cycles |
- 1) The enclosure rating classes specified only apply while the thermometer is connected with female connectors that provide the corresponding enclosure rating.2) The pressure transmitter must be supplied with power by a limited energy circuit compliant with 9.3 of UL/EN/IEC 601010-1 or LPS to UL/EN/IEC 60950-1 or Class 2 to UL 1310/UL1585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m if the pressure transmitter is used above this altitude.
Ambient data
Ambient temperature operation | ?30 ?C … +100 ?C |
Storage temperature | ?30 ?C … +100 ?C |
Shock load | 40 g (6 ms) according to IEC 60068-2-27 (mechanical shock) |
Vibration load | 20 g (20 Hz … 2000 Hz, 120 min) according to IEC 60068-2-6 (vibration at resonance) |
Classifications
ECl@ss 5.0 | 27200614 |
ECl@ss 5.1.4 | 27200614 |
ECl@ss 6.0 | 27200614 |
ECl@ss 6.2 | 27200614 |
ECl@ss 7.0 | 27200614 |
ECl@ss 8.0 | 27200614 |
ECl@ss 8.1 | 27200614 |
ECl@ss 9.0 | 27200614 |
ETIM 5.0 | EC002476 |
ETIM 6.0 | EC002476 |
UNSPSC 16.0901 | 41112410 |