Mô tả sản phẩm
Product characteristics |
Electrical design |
PNP |
Output function |
normally open |
Sensing range [mm] |
22 |
Housing |
threaded type |
Dimensions [mm] |
M30 x 1.5 / L = 70 |
Application |
Special feature |
Gold-plated contacts; Increased sensing range |
Application |
Use in mobile and harsh applications |
Electrical data |
Operating voltage [V] |
10…60 DC |
Current consumption [mA] |
< 10 |
Protection class |
II |
Reverse polarity protection |
yes |
Outputs |
Electrical design |
PNP |
Output function |
normally open |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Switching frequency DC [Hz] |
100 |
Short-circuit protection |
yes |
Overload protection |
yes |
Detection zone |
Sensing range [mm] |
22 |
Real sensing range Sr [mm] |
22 ? 10 % |
Operating distance [mm] |
0…17.82 |
Increased sensing range |
yes |
Accuracy / deviations |
Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35 |
Hysteresis [% of Sr] |
1…20 |
Switch point drift [% of Sr] |
-10…10 |
Operating conditions |
Ambient temperature [?C] |
-40…85 |
Protection |
IP 67; IP 69K |
Tests / approvals |
EMC |
automotive area |
|
noise emission and noise interference according to the automotive directive 95/54/EC |
E1 type approval |
noise immunity according to DIN ISO 11452-2 |
100 V/m |
conducted interference acc. to ISO 7637-2 |
|
pulse |
1 2 3a 3b 4 5 |
severity level |
IV IV IV IV IV IV |
failure criterion |
C C A A A C |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
0,5 kV mains line to line |
EN 61000-4-6 HF conducted |
10 V |
EN 55011 |
class B |
|
Vibration resistance |
EN 60068-2-6 Fc |
20 g (10…3000 Hz) / -20…50 ?C |
|
50 sweep cycles per frequency; 1 octave per minute in 3 axes |
|
Shock resistance |
EN 60068-2-27 Ea |
100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40…85 ?C |
|
Continuous shock resistance |
EN 60068-2-27 |
40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20…50 ?C |
|
Fast temperature change |
EN 60068-2-14 Na |
TA = -40 ?C; TB = 85 ?C; t1 = 30 min; t2 = < 10 s; 50 cycles |
|
Salt spray test |
EN 60068-2-52 Kb |
severity level 5 (4 test cycles) |
|
MTTF [years] |
900 |
UL approval |
Ta |
0…40 ?C |
Enclosure type |
Type 1 |
voltage supply |
Class 2 |
File number UL |
E174191 |
|
Mechanical data |
Weight [g] |
117.8 |
Housing |
threaded type |
Mounting |
non-flush mountable |
Dimensions [mm] |
M30 x 1.5 / L = 70 |
Thread designation |
M30 x 1.5 |
Materials |
threaded sleeve: stainless steel; sensing face: LCP natural; connector housing: PEI; lock nuts: brass |
Displays / operating elements |
Display |
switching status |
4 x 90? LED, yellow |
|
Accessories |
Accessories (supplied) |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection – plug |
Connection |
Connector: 1 x M12; Contacts: gold-plated |