Mô tả sản phẩm
Distance sensors
Measurement principle | HDDM+ |
Measuring range |
0.2 m … 155 m, 6 % remission 1) 2) 3) 0.2 m … 460 m, 90 % remission 1) 2) 3) |
Target | Natural objects |
Resolution | 0.001 mm … 100 mm, adjustable 4) |
Repeatability | ? 1 mm, See repeatability characteristic lines 1) 5) 6) 7) |
Accuracy |
? 10 mm 0.2 m … 50 m 8) ? 20 mm 50 m … 100 m 8) ? 24 mm 100 m … 200 m 8) |
Response time | 3 ms … 384 ms 7) |
Measurement cycle time |
1 ms 4 ms 16 ms 64 ms 128 ms |
Output time | ? 1 ms 9) |
Light source |
Measurement laser, infrared (905 nm) Alignment laser, red (650 nm) |
Laser class | 1, even with simultaneous operation of measurement and alignment laser (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) |
5 mm x 20 mm (at 1 m) 10) 20 mm x 20 mm (at 10 m) 10) 140 mm x 30 mm (at 50 m) 10) 280 mm x 60 mm (at 100 m) 10) 560 mm x 120 mm (at 200 m) 10) |
Filter |
Rain and snow filter Fog filter Moving average distance value Kalman filter Moving average speed value |
Max. object temperature | +1,400 ?C 11) |
Additional function | Selection of relevant distance and signal level range, Selection of first or last echo in selected distance and signal level range |
Average laser service life (at 25 ?C) | 100,000 h 12) |
Max. movement speed | 128 m/s |
- 1) With max. ambient light 100 kLux sunlight.2) See measuring range diagram.3) Dependent on remission and measuring cycle time.4) Data interface resolution.5) Statistical error 1 ?, environmental conditions constant, min. warm-up time > about 15 min.6) 6 % … 90 % remission.7) Dependent on selected filter settings and measuring cycle time.8) At T = +23 ?C and after warm-up time > about 15 min.9) Depending on interface used.10) See light spot size diagram.11) For object temperatures > +1,200 ?C, the use of the additional filter is required for high-temperature applications. The additional filter reduces the measuring range limit by approx. 25%.12) Measuring laser.
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
Digital inputs | Internal pull-down circuit HIGH switching voltage: min. 13 V … max. supply voltageLOW switching voltage: max. 5 Vswitching functions: deactivate measuring laser, activate alignment laser, preset |
||||||||||||
Digital outputs | Push?pull Max. switching current of 100 mA, short-circuit protectedSwitching voltage Vs – 4 V |
||||||||||||
Analog output | 4 mA … 20 mA, scalable 1) | ||||||||||||
Resolution analog output | 16 bit |
- 1) Max. load = (Uv – 7 V) / 21.5 mA.
Supply voltage Vs | DC 18 V … 30 V, reverse polarity protected |
Ripple | ? 5 Vpp 1) |
Power consumption |
? 10 W (With heating switched off) 2) ? 17 W (With heating switched on) 2) |
Initialization time | < 15 s |
Housing material |
Aluminum alloy (AlSi12) Stone, ceramic, glass Polycarbonate PA |
Connection type | Round connector M12 x 1 |
Indication | Graphical, resistive touch display, status LEDs |
Weight | 980 g |
Enclosure rating |
IP65 3) IP67 3) |
Protection class | III (EN 61140) |
- 1) May not fall short of or exceed VS tolerances.2) Without external load.3) When plugged in with a suitable mating connector.
Ambient temperature operation |
?40 ?C … +55 ?C 1) ?40 ?C … +95 ?C, operation with cooling case |
Ambient storage temperature | ?40 ?C … +75 ?C |
Max. rel. humidity (not condensing) | ? 95 % |
Effect of air pressure | 0.3 ppm/hPa |
Effect of air temperature | ?1 ppm/K |
Temperature drift | Typ. 0.25 mm/K |
Typ. Ambient light immunity | ? 100,000 lx |
Mechanical load |
Shock: 30 g / 6 ms according to DIN EN 60068-2-27 (Ea), 6 axes Continuous shock: 25 g / 6 ms according to DIN EN 60068-2-27 (fatigue), 500 shocks, 6 axes |
- 1) At a temperature of ?40 ?C, a warm-up time of typ. 20 minutes is required (when supply voltage Vs = 24 V).
ECl@ss 5.0 | 27270801 |
ECl@ss 5.1.4 | 27270801 |
ECl@ss 6.0 | 27270801 |
ECl@ss 6.2 | 27270801 |
ECl@ss 7.0 | 27270801 |
ECl@ss 8.0 | 27270801 |
ECl@ss 8.1 | 27270801 |
ECl@ss 9.0 | 27270801 |
ETIM 5.0 | EC001825 |
ETIM 6.0 | EC001825 |
UNSPSC 16.0901 | 41111613 |