WLA26P-1H162100A00

5,779,000

Tên sản phẩm: Compact photoelectric sensors W26

Danh mục: Photoelectric sensors

Model: WLA26P-1H162100A00

ID: 1218822

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1218822 Danh mục:

Mô tả sản phẩm

Photoelectric sensors

Features
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 24.6 mm x 82.5 mm x 53.3 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 18 m 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) ? 100 mm (10 m)
Wave length 635 nm
Adjustment

BluePilot: With alignment aid

IO-Link

Pin 2 configuration External Input (test), Teach-in, switching signal
    1) Reflector PL80A.2) Average service life: 100,000 h at TU = +25 ?C.
Mechanics/electronics
Supply voltage 10 V DC … 30 V DC 1)
Ripple ? 5 Vpp
Power consumption

30 mA 2)

50 mA 3)

Switching output

PUSH/PULL

PNP

NPN

Output: QL1 / C Switching output or IO-Link mode
Output function Factory setting: Pin 2 (MF): NPN normally closed (light switching), PNP normally open (dark switching), Pin 4 (QL1/C): NPN normally open (dark switching), PNP normally closed (light switching), IO-Link
Switching mode Light/dark switching
Signal voltage PNP HIGH/LOW Approx. VS ? 2.5 V / 0 V
Signal voltage NPN HIGH/LOW Approx. VS / < 2.5 V
Output current Imax. ? 100 mA
Response time ? 500 ?s 4)
Switching frequency 1,000 Hz 5)
Connection type Cable, 2 m 6)
Cable material PVC
Circuit protection

A 7)

B 8)

C 9)

D 10)

Protection class III
Weight 130 g
Polarisation filter ?
IO-Link ?
Housing material Plastic, VISTAL?
Optics material Plastic, PMMA
Enclosure rating

IP66

IP67

Ambient operating temperature ?40 ?C … +60 ?C
Ambient storage temperature ?40 ?C … +75 ?C
MTTFd: mean time to dangerous failure 627 years
UL File No. NRKH.E181493 & NRKH7.E181493
    1) Limit values.2) 16 V DC … 30 V DC, without load.3) 10 V DC … 16 V DC, without load.4) Signal transit time with resistive load in switching mode. Different values possible in COM2 mode.5) With light/dark ratio 1:1 in switching mode. Different values possible in IO-Link mode.6) Do not bend below 0 ?C.7) A = VS connections reverse-polarity protected.8) B = inputs and output reverse-polarity protected.9) C = interference suppression.10) D = outputs overcurrent and short-circuit protected.
Classifications
ECl@ss 5.0 27270904
ECl@ss 5.1.4 27270904
ECl@ss 6.0 27270904
ECl@ss 6.2 27270904
ECl@ss 7.0 27270904
ECl@ss 8.0 27270904
ECl@ss 8.1 27270904
ECl@ss 9.0 27270904
ETIM 5.0 EC002719
ETIM 6.0 EC002719
UNSPSC 16.0901 39121528
Smart Task
Smart Task name Base logics
Logic function

Direct

AND

OR

Window

Hysteresis

Timer function

Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Switching frequency

SIO Direct: 1000 Hz 1)

SIO Logic: 800 Hz 2)

IOL: 650 Hz 3)

Response time

SIO Direct: 500 ?s 1)

SIO Logic: 600 ?s 2)

IOL: 750 ?s 3)

Repeatability

SIO Direct: 150 ?s 1)

SIO Logic: 300 ?s 2)

IOL: 400 ?s 3)

Switching signal QL1 Switching output
Switching signal QL2 Switching output
    1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure

Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = empty

VendorID 26
DeviceID HEX 0x800180
DeviceID DEZ 8388992