UE11-4DX3D33

5,123,000

Tên sản phẩm: Safety relays UE11-4DX

Danh mục: sens:Control – safe control solutions

Model: UE11-4DX3D33

ID: 6024928

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 6024928 Danh mục:

Mô tả sản phẩm

sens:Control – safe control solutions

Safety-related parameters
Safety integrity level

SIL2 (IEC 61508) 1)

SILCL2 (EN 62061) 1)

Category Category 3 (EN ISO 13849) 1)
Performance level PL d (EN ISO 13849) 1)
B10d parameter

1 x 106 switching cycles (AC-15, 230 V, I = 0.5 A)

3.5 x 105 switching cycles (DC-13, 24 V, I = 2 A)

1.2 x 106 switching cycles (DC-13, 24 V, I = 0.5 A)

PFHD (mean probability of a dangerous failure per hour) 2.0 x 10-7 (EN ISO 13849)
TM (mission time) 4 years (EN ISO 13849)
    1) If the feedback current path Y1 – Y2 (external device monitoring) is monitored using an appropriate main unit.
Interfaces
Connection type Plug-in screw-type terminals
Number of enable current (N/O) contacts 4, relevant for safety
Electrical data – Operating data
Voltage supply A1, A2
Output circuit > 25 V AC / 60 V DC PELV
Output circuit ? 25 V AC / 60 V DC PELV or SELV
Supply voltage VS A1, A2
24 V DC (20.4 V DC … 26.4 V DC)
Residual ripple (? 2.4 Vpp) 1)
Power consumption (? 1 W (DC))
Overvoltage category III (see operating instructions)
Rated insulation voltage Ui 300 V AC
Rated impulse withstand voltage Uimp 4 kV
Test voltage 2 kV (50 Hz) (EN 60439-1)
    1) In DC operation, within the limits of VS.
Electrical data – Electrical output circuits: 17/18, 27/28, 37/38, 47/48, 55/56, 65/66, Y1/Y2
Off-delay time 3 s
Number of enable current (N/O) contacts 4, relevant for safety
Number of signalling current (N/C) contacts 2, not safety-relevant
Number of contactor monitoring (N/C) contacts 1, external device monitoring (EDM)
Contact type Positively driven
Contact material Silver alloy, gold flashed
Switching voltage
Enable current contact 10 V AC … 230 V AC
10 V DC … 300 V DC
Signalling current contact 10 V DC, 10 V DC … 230 V AC, 300 V DC
Current-carrying capacity per OSSD
Enable current contact 10 mA … 6 A
Signalling current contact 10 mA … 2 A
Contactor monitoring contact 10 mA … 100 mA
Total current ? 12 A
Usage category AC-15/DC-13 (EN 60947-5-1)
Rated operating current (voltage)

3 A (230 V AC) 3600 switching cycles/h

4 A (24 V DC) 360 switching cycles/h

2.5 A (24 V DC) 3600 switching cycles/h

Switching frequency ? 3600/h
Mechanical life (relay contacts) 1 x 107 switching cycles
Electrical life (relay contacts) 2 x 106 switching cycles
Mechanical data
Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm
Weight 0.2 kg
Classifications
ECl@ss 5.0 27371990
ECl@ss 5.1.4 27371990
ECl@ss 6.0 27371819
ECl@ss 6.2 27371819
ECl@ss 7.0 27371819
ECl@ss 8.0 27371819
ECl@ss 8.1 27371819
ECl@ss 9.0 27371819
ETIM 5.0 EC001449
ETIM 6.0 EC001449
UNSPSC 16.0901 41113704