Mô tả sản phẩm
Detection and ranging solutions
Features
Measurement principle | HDDM | ||||
Application | Indoor | ||||
Light source | Infrared (850 nm) | ||||
Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) | ||||
|
|||||
Scanning frequency | 15 Hz | ||||
Angular resolution | 0.33? | ||||
Working range | 0.05 m … 10 m ( > 50% remission) | ||||
Safety-related working range | 0.05 m … 4 m (At 5% remission) | ||||
Blind zone | 0 m … 0.05 m |
Safety-related parameters
Category | B (EN ISO 13849-1:2015) |
Performance level | PL b (EN ISO 13849-1:2015) |
MTTFD (mean time to dangerous failure) | 100 years |
TM (mission time) | 10 years (EN ISO 13849-1:2015) |
Performance
Response time |
1 scan, typ. 67 ms 2 scans, ? 134 ms |
Integrated application | Protective field evaluation with flexible fields |
Protective field tolerance | 100 mm, 0.66? (DIN CLC/TS 62046:2009, 5% remission) |
Number of field sets | 16 field triples (48 protective fields) |
Simultaneous evaluation cases | 3 simultaneous protective fields (per field set) |
Interfaces
|
|||||||
Switching inputs | 4 (PNP, for field set switching) | ||||||
Switching outputs | 3 (PNP, to display a protective field violation, additional 1 x ?Device Ready?) | ||||||
Delay time | 67 ms … 30,000 ms (configurable) | ||||||
Dwell time | 67 ms … 10,000 ms (configurable) | ||||||
Optical indicators | 2 LEDs (ON, switching status) |
Mechanics/electronics
Electrical connection |
1 x ?Ethernet? connection, 4-pin M12 female connector 1 x connection ?Power?, 12-pin, M12 male connector 1 x Micro USB female connector, type B |
Supply voltage | 9 V DC … 28 V DC |
Power consumption | 16 W, With 4 max. loaded switching outputs |
Housing color | Yellow |
Enclosure rating | IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013) |
Protection class | III (IEC 61140:2016-1) |
Weight | 250 g, without connecting cables |
Dimensions (L x W x H) | 60 mm x 60 mm x 86 mm |
Ambient data
Electromagnetic compatibility (EMC) | IEC 61000-6-3:2006+AMD1:2010 / IEC 61000-6-2:2005 |
Vibration resistance | IEC 60068-2-6:2007 |
Shock resistance | IEC 60068-2-27:2008 |
Ambient operating temperature | ?10 ?C … +50 ?C |
Storage temperature | ?40 ?C … +75 ?C |
General notes
Note on use | The TiM361S is a safety-related sensor that is suitable for use in the following applications: hazardous area, hazardous point, and access protection as well as mobile hazardous area protection (protection of automated guided vehicles and mobile platforms). The sensor must only ever be used within the limits of the prescribed and specified technical data and operating conditions. |
Classifications
ECl@ss 5.0 | 27270990 |
ECl@ss 5.1.4 | 27270990 |
ECl@ss 6.0 | 27270913 |
ECl@ss 6.2 | 27270913 |
ECl@ss 7.0 | 27270913 |
ECl@ss 8.0 | 27270913 |
ECl@ss 8.1 | 27270913 |
ECl@ss 9.0 | 27270913 |
ETIM 5.0 | EC002550 |
ETIM 6.0 | EC002550 |
UNSPSC 16.0901 | 46171620 |