SAPPD2D-06AP008

Tên sản phẩm: Safety systems Safeguard Detector / Box variant / 10 Hz

Danh mục: Safety systems and solutions

Model: SAPPD2D-06AP008

ID: 1089571

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1089571 Danh mục:

Mô tả sản phẩm

Safety systems and solutions

Safety-related parameters of the safety system
Safety integrity level

SIL2 (IEC 61508)

SILCL2 (EN 62061)

Category Category 3 (EN ISO 13849-1)
Performance level PL d (EN ISO 13849-1)
PFHD (mean probability of a dangerous failure per hour) 1.5 * 10-7
DCavg (diagnostic coverage) 80 % (EN ISO 13849-1)
MTTFD (mean time to dangerous failure) 250 years (EN ISO 13849-1)
CCF (common cause failure) Fulfilled (EN ISO 13849-1)
TM (mission time) 20 years (EN ISO 13849-1)
UE410-SD safety evaluation module
Note The UE410-SD safety evaluation module can be operated with one or two MultiPulse sensor pairs. The actuator can be connected directly to the UE410-SD safety evaluation module. The safety chain can also be expanded with additional logic elements (e.g., a higher-level safety controller).
Configuration method Hard wired
Number of connectable sensor pairs 1 or 2
Connection type Screw-type terminals
Pulse rate of the sensors 10 Hz
Supply voltage VS 24 V DC (19.2 V … 30 V)
Protection class III (EN 50178)
Enclosure rating IP20 (EN 60529)
Ambient operating temperature ?25 ?C … 55 ?C
Response time of the overall safety system (sensors and safety evaluation module) ? 160 ms
MultiPulse photoelectric proximity sensor
Number of sensors 4 pieces
Detection zone 30 mm … 100 mm 1)
Remission 6 % … 90 %
Pulse frequency 10 Hz
Response time ? 100 ms
Type of light Visible red light
Wave length 650 nm
Light spot size (distance) ? 7 mm (50 mm)
Connection type Connector M8, 3-pin
Voltage supply Via UE410-SD
Enclosure rating IP67 (EN 60529)
Ambient operating temperature ?40 ?C … +60 ?C
    1) If no movable physical guard is identified in the detection zone, the safety controller prompts the machine to enter the safe state.