Mô tả sản phẩm
Safety switches
Features
System part | Sensor and actuator |
Sensor principle | Magnetic |
Number of N/O contacts | 2 |
Number of N/C contacts | 0 |
Number of signaling contacts | 0 |
Safe switch on distance Sao | 9 mm |
Safe switch off distance Sar | 22 mm |
Active sensor surfaces | 1 |
Actuation directions | 3 |
Safety-related parameters
B10d parameter | 2 x 107 switching cycles (with small load) |
Type | Type 4 (EN ISO 14119) |
Actuator coding level | Low coding level (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Functions
Safe series connection | No |
Interfaces
|
Electrical data
Type of output | Reed contacts |
Switching voltage | ? 30 V DC |
Switching current | ? 100 mA |
Mechanical data
Design | Rectangular |
Dimensions (W x H x D) | 25 mm x 88 mm x 13 mm |
Weight | 0.3 kg |
Housing material | Glass-fiber reinforced PPS |
Ambient data
Enclosure rating | IP67 (IEC 60529) |
Ambient operating temperature | ?20 ?C … +60 ?C |
Storage temperature | ?20 ?C … +60 ?C |
Vibration resistance | 10 Hz … 55 Hz, 1 mm (EN 60947-5-3) |
Shock resistance | 30 g, 11 ms (EN 60947-5-3) |
Classifications
ECl@ss 5.0 | 27272402 |
ECl@ss 5.1.4 | 27272402 |
ECl@ss 6.0 | 27272402 |
ECl@ss 6.2 | 27272402 |
ECl@ss 7.0 | 27272402 |
ECl@ss 8.0 | 27272402 |
ECl@ss 8.1 | 27272402 |
ECl@ss 9.0 | 27272402 |
ETIM 5.0 | EC002544 |
ETIM 6.0 | EC002544 |
UNSPSC 16.0901 | 39122205 |