Mô tả sản phẩm
Registration sensors
Features
Sensor principle | Delta-S-Technology? |
Dimensions (W x H x D) | 42.5 mm x 44 mm x 43.4 mm |
Sensing distance | 50 mm |
Sensing distance tolerance | ? 5 mm |
Housing design (light emission) | Rectangular |
Tilt angle tolerance | ? 5? |
Minimum detectable object (MDO) | 12 x 14 mm |
Light source | LED, Red 1) |
Wave length | 640 nm |
Light spot size | 10 mm x 12 mm |
Object speed max. | 2 m/s 2) |
Sensitivity | Fine, middle, coarse |
Adjustment | Potentiometer, cable, Single teach-in button (Sensitivity (Q, Q/, teach-in), Teach-in, Teach-in) 3) |
Teach-in mode |
Static 1-point teach-in Static 2-point teach-in Dynamic 2-point teach-in Static 3-point teach-in |
- 1) Average service life: 100,000 h at TU = +25 ?C.2) Minimum object size.3) HIGH = > VS – 2 V / LOW = open or < 2 V.
Interfaces
Advanced functions | None |
Fieldbus, industrial network | – |
Type of fieldbus integration | – |
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | ? 5 Vpp 2) |
Power consumption | < 150 mA 3) |
Switching frequency | 500 Hz 4) |
Response time | 1 ms 5) |
Jitter | 500 ?s |
Number of switching outputs | 2 (Q1, Q2) |
Switching output | PUSH/PULL |
Switching output (voltage) | Push/Pull (High: VS – 3 V, Low: < 3 V) |
Output current Imax. | < 100 mA 6) |
Initialization time | < 2.5 s |
Connection type | Male connector M12, 5-pin |
Ambient light immunity | > 50 klx |
Circuit protection |
A 7) C 8) D 9) |
Protection class | III |
Enclosure rating | IP67 |
Weight | + 130 g |
Housing material | ABS |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) With light/dark ratio 1:1.5) Signal transit time with resistive load.6) Consumption count Q1 / Q2.7) A = VS connections reverse-polarity protected.8) C = interference suppression.9) D = outputs overcurrent and short-circuit protected.
Ambient data
Ambient operating temperature | ?10 ?C … +55 ?C |
Ambient storage temperature | ?25 ?C … +75 ?C |
Shock load | According to EN 60068-2-27, single shock (30 g/11 MS), continuous shock (25 g/11 MS) |
UL File No. | NRKH.E181493 |
Classifications
ECl@ss 5.0 | 27270906 |
ECl@ss 5.1.4 | 27270906 |
ECl@ss 6.0 | 27270906 |
ECl@ss 6.2 | 27270906 |
ECl@ss 7.0 | 27270906 |
ECl@ss 8.0 | 27270906 |
ECl@ss 8.1 | 27270906 |
ECl@ss 9.0 | 27270906 |
ETIM 5.0 | EC001820 |
ETIM 6.0 | EC001820 |
UNSPSC 16.0901 | 39121528 |