Distance sensors

Features
System part Sensor head
Performance
Measuring range 65 mm … 105 mm 1)
Target Natural objects
Repeatability 5 ?m 2)
Linearity ? 40 ?m 2)
Response time ? 0.5 ms 3)
Measuring frequency ? 10 kHz
Output time ? 0.1 ms
Light source Laser, red
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 4)
Typ. light spot size (distance) 70 ?m x 290 ?m (85 mm)
    1) 6 % … 90 % remission.2) Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror, averaging set to: 256, constant ambient conditions.3) Dependent on the set average or sensitivity.4) Wavelength: 650 nm, max. output: 390 ?W (laser class 1) / 1 mW (laser class 2).
Interfaces
Serial ? , RS-232
Type of fieldbus integration Optional, over external evaluation unit AOD
Digital output
Number 5 1)
Type PNP / NPN
Maximum output current IA ? 100 mA
Analog output 2 x 4 mA … 20 mA (? 300 ?) 1)
    1) Optional over evaluation unit AOD.
Mechanics/electronics
Warm-up time ? 5 min
Housing material Aluminum
Window material Glass
Connection type 0.5 m cable with connector 1) 2)
Indication LEDs, 1.4” color display on evaluation unit
Weight 250 g 3)
Enclosure rating IP67
Protection class III
    1) Can be extended to up to 10 m with extension cable.2) Sensor must be connected to controller unit.3) Includes 0.5 m cable.
Ambient data
Ambient temperature operation ?10 ?C … +45 ?C
Ambient storage temperature ?20 ?C … +60 ?C
Relative air humidity (non-condensing) 35 % … 85 %
Temperature drift ? 0.01 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunity

Artificial light: ? 3,000 lx

Sunlight: ? 10,000 lx

Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance 50 G (x, y, z axis 3 times each)
General notes
Note on use OD Max sensor head OD25-x is only to be used with AODG-P/N1, All other types (OD350-x, OD85-x, OD30-x) are to be used with AOD-P/N1
Classifications
ECl@ss 5.0 27270801
ECl@ss 5.1.4 27270801
ECl@ss 6.0 27270801
ECl@ss 6.2 27270801
ECl@ss 7.0 27270801
ECl@ss 8.0 27270801
ECl@ss 8.1 27270801
ECl@ss 9.0 27270801
ETIM 5.0 EC001825
ETIM 6.0 EC001825
UNSPSC 16.0901 41111613