Detection and ranging solutions

Features
Measurement principle HDDM+
Application Outdoor
Light source Infrared (850 nm)
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
Aperture angle
Horizontal 275?
Scanning frequency 150 Hz, 4 x 37,5 Hz
Angular resolution 0.75?
Heating No
Working range 0.2 m … 64 m
Scanning range
At 10% remission 16 m
At 90% remission 30 m
Spot size 10.4 mrad x 34.9 mrad
Amount of evaluated echoes 3
Performance
Scan/frame rate 55,000 measurement point/s … 165,000 measurement point/s
Response time 20 ms
Systematic error ? 60 mm
Statistical error ? 30 mm
Integrated application Integrated field evaluation with flexible fields, Data output
Number of field sets Up to 10 fields
Simultaneous evaluation cases Up to 6 evaluations
Filter

Fog filter

Particle filter

Average filter

Median filter

Interfaces
Ethernet ? , TCP/IP, UDP/IP
Function Host, OPC, NTP, Measured data output (distance, RSSI)
Data transmission rate 10/100 MBit/s
Switching inputs and outputs I/O (8 (Multiport))
Optical indicators LEDs
Configuration software SOPAS ET, Web server (display)
Mechanics/electronics
Electrical connection M12 round connectors (D-coded, aligned) with swivel connector
Supply voltage 10 V … 30 V
Power consumption ? 18 W, Power-up max. 35 W for 5 s
Housing AlMG4,5
Housing color Gray (RAL 7042)
Enclosure rating IP65, IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class III
Weight 1.2 kg
Dimensions (L x W x H) 151.9 mm x 150 mm x 92.5 mm
Ambient data
Object remission 2 % … > 1,000 % (Reflector)
Electromagnetic compatibility (EMC)

EN 61000-6-1 (2007-10)

EN 61000-6-2:2005-08

EN 61000-6-3 (2007-01)

Vibration resistance IEC 60068-2-6:2007
Shock resistance IEC 60068-2-27:2008
Ambient operating temperature ?30 ?C … +50 ?C
Storage temperature ?40 ?C … +75 ?C
Ambient light immunity 80 klx
General notes
Note on use The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
Classifications
ECl@ss 5.0 27270990
ECl@ss 5.1.4 27270990
ECl@ss 6.0 27270913
ECl@ss 6.2 27270913
ECl@ss 7.0 27270913
ECl@ss 8.0 27270913
ECl@ss 8.1 27270913
ECl@ss 9.0 27270913
ETIM 5.0 EC002550
ETIM 6.0 EC002550
UNSPSC 16.0901 46171620