KHK53-AXT00548

Tên sản phẩm: Linear encoders KH53

Danh mục: Product portfolio

Model: KHK53-AXT00548

ID: 1035448

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1035448 Danh mục:

Mô tả sản phẩm

Product portfolio

Safety-related parameters
MTTFd: mean time to dangerous failure 22 years (EN ISO 13849) 1)
    1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40?C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Performance
Measuring length 0 m … 548 m
Measuring range 548 m
Resolution 0.1 mm
Traversing speed 6.6 m/s 1)
Repeatability 1 mm
Measurement accuracy ? 2000 + ME (Tu-25? C) Tk ?m 2)
    1) If the max. traversing speed is exceeded or if the measuring elements are left, the corresponding error message is triggered (with SSI: FF FF FE hex).2) If a positional tolerance of ? 1 mm is observed relative to the nominal distance in the N and Y directions within a measuring element relative to the starting point of this element ME = length of measuring element Tu = ambient temperature in ?C. Tk = coefficient of thermal expansion (see ?Mechanical data? table).
Interfaces
Communication interface SSI
Position forming time + 0.8 ms
Interface, digital serial SSI, 24 Bit, gray
Interface for parametrization

RS-422

Default OFF

Four wire transmission, asynchrony, full duplex

Data format: 1 start bit, 8 data bits, 1 stop bit, no parity

Data protocol: ASCII, Baud rate 9600 RS-422

Electrical data
Initialization time 2 s
Supply voltage 10 V … 32 V
Power consumption 250 mA
Connection type Cable, 12-wire, 5 m
MTTFd: mean time to dangerous failure 22 years (EN ISO 13849) 1)
    1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40?C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Mechanical data
Weight 6.7 kg
Length of measuring element See calculation example
Position tolerance ? 20 mm, see positional tolerances diagram
Read head material AlMgSiPbF28
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-4 1)
Enclosure rating IP66 (IEC 60529)
Operating temperature range ?30 ?C … +70 ?C
Storage temperature range ?40 ?C … +85 ?C
Resistance to shocks 30 g, 10 ms (DIN EN 60 068-2-27)
Resistance to vibration 10 g, 20 Hz … 250 Hz (EN 60068-2-6)
    1) EMC according to the standards quoted is achieved if shielded cables are used.
Classifications
ECl@ss 5.0 27270705
ECl@ss 5.1.4 27270705
ECl@ss 6.0 27270705
ECl@ss 6.2 27270705
ECl@ss 7.0 27270705
ECl@ss 8.0 27270705
ECl@ss 8.1 27270705
ECl@ss 9.0 27270705
ETIM 5.0 EC002544
ETIM 6.0 EC002544
UNSPSC 16.0901 41111613