Mô tả sản phẩm
Proximity sensors
Features
Housing | Rectangular |
Dimensions (W x H x D) | 12 mm x 40 mm x 26 mm |
Sensing range Sn | 0 mm … 4 mm 1) |
Safe sensing range Sa | 3.24 mm |
Number of switching points | Up to 4 adjustable switching points or windows |
Switching modes | Single point, Window mode, Two point mode, Visual adjustment indicator |
Switching frequency Qint.1 / Qint.2 on Pin2 | 1,000 Hz |
Installation type | Flush |
Connection type | Cable with M12 male connector, 4-pin, 0.2 m 2) |
Switching output | PNP |
Output Q/C | Switching output or IO-Link mode |
Output MFC | Switching output or input |
Output function | NC / NO |
Output characteristic | Programmable |
Electrical wiring | DC 4-wire |
Enclosure rating | IP68 3) |
Special features | Smart Task |
Diagnosis | Chip temperature |
Pin 2 configuration | External input, Teach-in, switching signal |
- 1) Adjustable.2) With gold plated contact pins.3) According to EN 60529.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | ? 10 % |
Voltage drop | ? 2 V 2) |
Current consumption | 35 mA 3) |
Hysteresis | Programmable 4) |
Reproducibility | ? 5 % 5) 6) |
Temperature drift (of Sr) | ? 10 % |
EMC | According to EN 60947-5-2 |
Continuous current Ia | ? 200 mA 7) |
Short-circuit protection | ? |
Reverse polarity protection | ? |
Power-up pulse protection | ? |
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
Ambient operating temperature | ?25 ?C … +75 ?C |
Housing material | Plastic, VISTAL? |
Sensing face material | Plastic, VISTAL? |
Tightening torque, max. | < 1 Nm |
Teach-in accuracy | +/- 3% of Sr |
Resolution, typical (range) | 20 ?m (0 mm … 4 mm) |
Resolution, maximum (area) | 40 ?m (0 mm … 4 mm) |
- 1) IO-Link mode: 18 VDC … 30 VDC.2) At Ia max.3) Without load.4) To comply with EN 60947-5-2, a hysteresis of approx. 10% must be set.5) Ub and Ta constant.6) Of Sr.7) 200 mA total for both switching outputs.
Reference values
Note | Reference value in Digits for switching point in mm stored in the sensor |
Reference value 1 | 4 mm |
Reference value 2 | 3 mm |
Reference value 3 | 2 mm |
Reference value 4 | 1 mm |
Reduction factors
Stainless steel (V2A, 304) | Approx. 0.7 |
Aluminum (Al) | Approx. 0.4 |
Copper (Cu) | Approx. 0.3 |
Brass (Br) | Approx. 0.4 |
Installation note
Remark | Associated graphic see “Installation” |
A | 0 mm |
B | 12 mm |
C | 12 mm |
D | 12 mm |
E | 0 mm |
F | 32 mm |
G | 0 mm |
Classifications
ECl@ss 5.0 | 27270101 |
ECl@ss 5.1.4 | 27270101 |
ECl@ss 6.0 | 27270101 |
ECl@ss 6.2 | 27270101 |
ECl@ss 7.0 | 27270101 |
ECl@ss 8.0 | 27270101 |
ECl@ss 8.1 | 27270101 |
ECl@ss 9.0 | 27270101 |
ETIM 5.0 | EC002714 |
ETIM 6.0 | EC002714 |
UNSPSC 16.0901 | 39122230 |
Smart Task
Smart Task name | Base logics |
Logic function |
AND OR XOR Hysteresis |
Timer function |
On delay Off delay ON and OFF delay Impulse (one shot) |
Inverter | Adjustable |
Switching frequency |
SIO Direct: 1000 Hz 1) SIO Logic: 1000 Hz 2) IOL: 1000 Hz 3) |
Switching signal QL1 | Switching output |
Switching signal QL2 | Switching output |
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 5 ms |
Process data length | 32 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 = switching signal QInt3 Bit 3 = switching signal QInt4 Bit 16 … 31 = distance value |
Factory setting |
Switching Point 1: reference value 1 Output: normally open Pin 2 configuration: input |