Mô tả sản phẩm
Product characteristics |
Output function |
normally open |
Sensing range [mm] |
20 |
Housing |
rectangular |
Dimensions [mm] |
40 x 40 x 66 |
Electrical data |
Frequency AC [Hz] |
47…63 |
Operating voltage [V] |
20…140 AC / 10…140 DC |
Protection class |
I |
Reverse polarity protection |
yes |
Outputs |
Output function |
normally open |
Max. voltage drop switching output DC [V] |
5.5 |
Max. voltage drop switching output AC [V] |
5.5 |
Minimum load current [mA] |
5.5 |
Max. leakage current [mA] |
1.7 (140 V AC/DC) |
Permanent current rating of switching output AC [mA] |
450 |
Permanent current rating of switching output DC [mA] |
450 |
Short-time current rating of switching output [mA] |
2200; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] |
25 |
Switching frequency DC [Hz] |
100 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Detection zone |
Sensing range [mm] |
20 |
Real sensing range Sr [mm] |
20 ? 10 % |
Operating distance [mm] |
0…16.2 |
Accuracy / deviations |
Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] |
3…20 |
Switch point drift [% of Sr] |
-10…10 |
Operating conditions |
Ambient temperature [?C] |
-25…70 |
Protection |
IP 67 |
Tests / approvals |
EMC |
|
MTTF [years] |
351 |
UL approval |
Ta |
0…40 ?C |
Enclosure type |
Type 1 |
voltage supply |
Hazardous voltage |
File number UL |
E174191 |
|
Mechanical data |
Weight [g] |
270.5 |
Housing |
rectangular |
Mounting |
flush mountable |
Dimensions [mm] |
40 x 40 x 66 |
Materials |
housing: PPE; sensing face: PPE; end cap: diecast zinc; connector housing: brass white bronze coated; clamp: diecast zinc |
Displays / operating elements |
Display |
switching status |
1 x LED, red |
operation |
1 x LED, green |
short circuit |
1 x LED, green/red alternately flashing |
|
Remarks |
Remarks |
5 positions of the active zone possible |
|
Pack quantity |
1 pcs. |
Electrical connection – plug |
|
Connector: 1 x 7/8″ |