Mô tả sản phẩm
Product characteristics |
Dimensions [mm] |
90 x 62 x 33.2 |
Inclination measurement |
Number of measurement axes |
2 |
Angular range [?] |
? 45 |
Application |
Application |
High-precision inclination measurement in 2 axes for mobile and industrial applications |
Electrical data |
Operating voltage [V] |
9.2…30 DC; (voltage output: 12…30 DC; IO-Link: 18…30 DC) |
Current consumption [mA] |
100; (24 V DC, 25 ?C) |
Max. current consumption [mA] |
380; (9,2 V DC, -40 ?C) |
Protection class |
III |
Reverse polarity protection |
yes |
Reverse polarity protection |
yes |
Max. initialisation time [ms] |
1000 |
Power-on delay time [s] |
300; (warm-up time) |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 2 |
Outputs |
Total number of outputs |
4 |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (programmable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
125; (125 mA (85? C); 200 mA (60? C); 250 mA (40? C)) |
Number of analogue outputs |
2 |
Analogue current output [mA] |
4…20; (in case of a fault: 2 mA) |
Max. load [?] |
220; (220 (9,2?15 V) / 500 (15?30 V)) |
Analogue voltage output [V] |
2…10; (in case of a fault: 1 V) |
Min. load resistance [?] |
1000; (10000 (12…13,5 V) / 1000 (13,5…30 V)) |
Precision analogue output [%] |
? 1 |
Short-circuit protection |
yes |
Overload protection |
yes |
Measuring/setting range |
Measuring?principle |
MEMS capacitive |
Inclination measurement |
Number of measurement axes |
2 |
Number of measurement axes |
2 |
Angular range [?] |
? 45 |
Angular range [?] |
? 45 |
Limit frequency [Hz] |
0.5…10; (parameterisable) |
Accuracy / deviations |
Accuracy [?] |
? ? 0,01 |
Repeatability [?] |
? ? 0,01 |
Resolution [?] |
0.01 |
Temperature coefficient [1/K] |
? ? 0,0008 |
Software / programming |
Parameter setting options |
angle (X/Y); hysteresis / window; switch points; switching logic; fault indication; self-test; current/voltage output |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
IO-Link device ID |
416 / 0x0001A0 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
5 |
Operating conditions |
Ambient temperature [?C] |
-40…85 |
Storage temperature [?C] |
-40…85 |
Protection |
IP 65; IP 67; IP 68; IP 69K |
Tests / approvals |
EMC |
DIN EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
DIN EN 61000-4-3 HF radiated |
10 V/m |
DIN EN 61000-4-4 Burst |
2 kV |
DIN EN 61000-4-6 HF conducted |
10 V |
DIN EN 55022 class B / CISPR 16-2-3 |
30 – 1000 MHz |
CISPR 25 ECE R 10 |
30 – 1000 MHz narrowband and broadband |
ISO 11452-2 ECE R 10 |
20 – 2000 MHz / 30 V/m |
ISO 7637-2 ECE R 10 |
pulse 1, 2a, 2b, 3a, 3b, 4, and pulse emission during operation, switching-on, switching-off |
ISO 7637-3 |
– 80 V pulse a / + 80 V pulse b |
|
Shock resistance |
DIN EN 60068-2-27 |
100 g 1 ms / 10000 impacts per axis (X/Y) |
DIN EN 60068-2-29 |
30 g 6 ms / 24000 shock (bump) |
|
Vibration resistance |
DIN EN 60068-2-64 |
10…2000 Hz Test VII / random, mounting place car body |
DIN EN 60068-2-6 |
10…500 Hz / 10 g 10 cycles/axis, sine |
|
Salt spray test |
DIN EN 60068-2-52 |
severity level 5 (motor vehicle) |
|
Damp heat |
DIN EN 60068-2-30 |
55 ?C cyclic upper temperature / 95 % rh 2 cycles of 24 h |
|
MTTF [years] |
176 |
Standard |
Compliant with ECE R 10, rev. 5; ISO 7637-3: 2007-07 |
Mechanical data |
Weight [g] |
451 |
Dimensions [mm] |
90 x 62 x 33.2 |
Materials |
housing: diecast zinc nickel-plated |
Displays / operating elements |
Display |
operation |
1 x LED, green |
switch point |
1 x LED, yellow |
|
Accessories |
Accessories (supplied) |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection – digital |
|
Connector: 1 x M12 |
Electrical connection – analogue |
|
Connector: 1 x M12 |
Other data |
Measuring/setting range |
inclination measurement |
|
|
|
|
|
|
|
min. |
max. |
switch point |
SP1 |
[?] |
-89.00 |
90.00 |
reset point |
rP1 |
[?] |
-90.00 |
89.00 |
switch point |
SP2 |
[?] |
-89.00 |
90.00 |
reset point |
rP2 |
[?] |
-90.00 |
89.00 |
Analogue start point |
ASP1 |
[?] |
-90.00 |
89.00 |
Analogue end point |
AEP1 |
[?] |
-89.00 |
90.00 |
Analogue start point |
ASP2 |
[?] |
-90.00 |
89.00 |
Analogue end point |
AEP2 |
[?] |
-89.00 |
90.00 |
In steps of |
|
[?] |