DL1000-S11101

Tên sản phẩm: Long range distance sensors Dx1000

Danh mục: Distance sensors

Model: DL1000-S11101

ID: 1075438

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1075438 Danh mục:

Mô tả sản phẩm

Distance sensors

Performance
Measurement principle HDDM+
Measuring range 0.2 m … 1,500 m, on reflective tape “Diamond Grade” 1) 2) 3)
Target Reflector
Resolution 0.001 mm … 100 mm, adjustable 4)
Repeatability ? 1 mm, See repeatability characteristic lines 1) 5) 6) 7)
Accuracy

? 20 mm 0.2 m … 2 m 8)

? 10 mm 5 m … 50 m 8)

? 20 mm 50 m … 100 m 8)

? 24 mm 300 m 8) 9)

? 48 mm 1.500 m 8)

Response time 3 ms … 384 ms 7)
Measurement cycle time

1 ms

4 ms

16 ms

Output time ? 1 ms 10)
Light source

Measurement laser, infrared (905 nm)

Alignment laser, red (650 nm)

Laser class 1, even with simultaneous operation of measurement and alignment laser (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance)

5 mm x 20 mm (at 1 m) 11)

20 mm x 20 mm (at 10 m) 11)

140 mm x 30 mm (at 50 m) 11)

280 mm x 60 mm (at 100 m) 11)

560 mm x 120 mm (at 200 m) 11)

4,200 mm x 900 mm (at 1,500 m) 11)

Filter

Rain and snow filter

Fog filter

Moving average distance value

Kalman filter

Moving average speed value

Additional function Selection of relevant distance and signal level range, Selection of first or last echo in selected distance and signal level range
Average laser service life (at 25 ?C) 100,000 h 12)
Max. movement speed 128 m/s
    1) With max. ambient light 100 kLux sunlight.2) See measuring range diagram.3) Dependent on reflector size and measuring cycle time.4) Data interface resolution.5) Statistical error 1 ?, environmental conditions constant, min. warm-up time > about 15 min.6) On reflective tape “Diamond Grade”.7) Dependent on selected filter settings and measuring cycle time.8) At T = +23 ?C and after warm-up time > about 15 min.9) Add ? 2 mm per 100 m (20 ppm).10) Depending on interface used.11) See light spot size diagram.12) Measuring laser.
Interfaces
Ethernet ? , TCP/IP
Function Parameterization, output of measurement data
Data transmission rate 10/100 MBit/s
Serial ? , RS-422
Remark Switchable to SSI
Function Parameterization, output of measurement data
SSI ?
Remark Switchable to RS-422
Function Output of measurement data
Inputs/outputs
In1/Q1 Digital input, digital output (Switchable)
QA/Q2 Analog output, digital output (Switchable)
Q3 Digital output
Q4 Digital output
In2 Digital input
Digital inputs Internal pull-down circuit
HIGH switching voltage: min. 13 V … max. supply voltageLOW switching voltage: max. 5 Vswitching functions: deactivate measuring laser, activate alignment laser, preset
Digital outputs Push?pull
Max. switching current of 100 mA, short-circuit protectedSwitching voltage Vs – 4 V
Analog output 4 mA … 20 mA, scalable 1)
Resolution analog output 16 bit
    1) Max. load = (Uv – 7 V) / 21.5 mA.
Mechanics/electronics
Supply voltage Vs DC 18 V … 30 V, reverse polarity protected
Ripple ? 5 Vpp 1)
Power consumption

? 10 W (With heating switched off) 2)

? 17 W (With heating switched on) 2)

Initialization time < 15 s
Housing material

Aluminum alloy (AlSi12)

Stone, ceramic, glass

Polycarbonate

PA

Connection type Round connector M12 x 1
Indication Graphical, resistive touch display, status LEDs
Weight 980 g
Enclosure rating

IP65 3)

IP67 3)

Protection class III (EN 61140)
    1) May not fall short of or exceed VS tolerances.2) Without external load.3) When plugged in with a suitable mating connector.
Ambient data
Ambient temperature operation

?40 ?C … +55 ?C 1)

?40 ?C … +95 ?C, operation with cooling case

Ambient storage temperature ?40 ?C … +75 ?C
Max. rel. humidity (not condensing) ? 95 %
Effect of air pressure 0.3 ppm/hPa
Effect of air temperature ?1 ppm/K
Temperature drift Typ. 0.25 mm/K
Typ. Ambient light immunity ? 100,000 lx
Mechanical load

Shock: 30 g / 6 ms according to DIN EN 60068-2-27 (Ea), 6 axes

Continuous shock: 25 g / 6 ms according to DIN EN 60068-2-27 (fatigue), 500 shocks, 6 axes

    1) At a temperature of ?40 ?C, a warm-up time of typ. 20 minutes is required (when supply voltage Vs = 24 V).
Classifications
ECl@ss 5.0 27270801
ECl@ss 5.1.4 27270801
ECl@ss 6.0 27270801
ECl@ss 6.2 27270801
ECl@ss 7.0 27270801
ECl@ss 8.0 27270801
ECl@ss 8.1 27270801
ECl@ss 9.0 27270801
ETIM 5.0 EC001825
ETIM 6.0 EC001825
UNSPSC 16.0901 41111613