Mô tả sản phẩm
Registration sensors
Dimensions (W x H x D) | 12 mm x 31.5 mm x 21 mm |
Sensing distance | 12.5 mm 1) |
Sensing distance tolerance | ? 3 mm |
Housing design (light emission) | Rectangular |
Light source | LED, RGB 2) |
Wave length | 640 nm, 525 nm, 470 nm |
Light spot size | 1.5 mm x 6.5 mm |
Light spot direction | Vertical |
Adjustment | Teach-in button |
Teach-in mode | 1-point teach-in |
- 1) From front edge of lens.2) Average service life: 100,000 h at TU = +25 ?C.
Supply voltage | 12 V DC … 24 V DC 1) |
Ripple | < 5 Vpp 2) |
Power consumption | < 50 mA 3) |
Switching frequency | 1.7 kHz 4) |
Response time | 300 ?s 5) |
Jitter | 150 ?s |
Switching output | PNP |
Switching output (voltage) | PNP: HIGH = VS? ? 2 V / LOW approx. 0 V |
Output (channel) | 8 colors via IO-Link |
Output current Imax. | < 100 mA 6) |
Input, teach-in (ET) |
PNP Teach: U = 10 V … < UV Run: U < 2 V or open |
Connection type | Cable with M12 male connector, 4-pin, 0.2 m |
Protection class | III |
Circuit protection |
UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP67 |
Weight | 25 g |
Housing material | ABS |
- 1) Limit values: DC 12 V (?10 %) … DC 24 V (+20 %). Operation in short-circuit protected network max. 8 A.2) May not exceed or fall below Uv tolerances.3) Without load.4) With light/dark ratio 1:1.5) Signal transit time with resistive load.6) At supply voltage > 24 V, Imax = 30 mA. Imax is consumption count of all Qn.
Ambient operating temperature | ?10 ?C … +55 ?C |
Ambient storage temperature | ?20 ?C … +75 ?C |
Shock load | According to IEC 60068 |
UL File No. | NRKH.E348498 & NRKH7.E348498 |
ECl@ss 5.0 | 27270907 |
ECl@ss 5.1.4 | 27270907 |
ECl@ss 6.0 | 27270907 |
ECl@ss 6.2 | 27270907 |
ECl@ss 7.0 | 27270907 |
ECl@ss 8.0 | 27270907 |
ECl@ss 8.1 | 27270907 |
ECl@ss 9.0 | 27270907 |
ETIM 5.0 | EC001817 |
ETIM 6.0 | EC001817 |
UNSPSC 16.0901 | 39121528 |
Communication interface |
IO-Link V1.0 IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure A |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 = Quality of Run Alarm Bit 3 … 5 = Emission Color Bit 6 ? 15 = Measurment Value RGB |
Process data structure B |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 3 = switching signal QL4 Bit 4 = switching signal QL5 Bit 5 = switching signal QL6 Bit 6 = switching signal QL7 Bit 7 = switching signal QL8 Bit 9 … 15 = empty |