Mô tả sản phẩm
Opto-electronic protective devices
Features
Scanning range |
0.5 m … 70 m, configurable |
Low scanning range |
0.5 m … 20 m |
Great scanning range |
9 m … 70 m |
Number of beams |
6 |
Beam separation |
220 mm |
Response time |
10 ms |
Synchronization |
Optical synchronisation |
End cap with integrated LED |
? |
Safety-related parameters
Type |
Type 4 (IEC 61496-1) |
Safety integrity level |
SIL3 (IEC 61508)
SILCL3 (EN 62061)
|
Category |
Category 4 (EN ISO 13849) |
Performance level |
PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) |
6.6 x 10-9 (EN ISO 13849) |
TM (mission time) |
20 years (EN ISO 13849) |
Safe state in the event of a fault |
At least one OSSD is in the OFF state. |
Functions
|
Functions |
Delivery status |
Restart interlock |
? |
Internal |
External device monitoring (EDM) |
? |
Activated |
Beam coding |
? |
Uncoded |
Sender test |
? |
Deactivated |
Configurable scanning range |
? |
0.5 m … 20 m |
Configurable application diagnostic output |
? |
Contamination (OWS) |
Safe SICK device communication via EFI |
? |
Muting |
? |
Interfaces
System connection |
|
Connection type |
Hirschmann male connector M26, 12-pin |
Permitted cable length |
? 50 m 1) |
Permitted cross-section |
? 0.75 mm? |
|
Extension connection |
|
Connection type |
Male connector M12, 5-pin |
|
Configuration method |
PC with CDS (Configuration and Diagnostic Software) |
|
Configuration connection |
|
Connection type |
Female connector M8, 4-pin |
|
Display elements |
LEDs
7-segment display
|
Fieldbus, industrial network |
|
Integration via EFI gateways |
CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 2) |
Integration via Flexi Soft safety controller |
CANopen, DeviceNet?, EtherCAT?, EtherNet/IP?, Modbus TCP, PROFIBUS DP, PROFINET 3) |
|
Electrical data
Protection class |
III (IEC 61140) |
Supply voltage VS |
24 V DC (19.2 V DC … 28.8 V DC) 1) |
Residual ripple |
? 10 % 2) |
Power consumption |
? 0.6 A 3) |
Output signal switching devices (OSSDs) |
|
Type of output |
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 4) |
ON state, switching voltage HIGH |
24 V DC (VS ? 2.25 V DC … VS) |
OFF state, switching voltage LOW |
? 2 V DC |
Current-carrying capacity per OSSD |
? 500 mA |
|
Diagnostic outputs |
|
Type of output |
PNP semiconductor, short-circuit protected |
ON state, switching voltage HIGH |
24 V DC (VS ? 4.2 V DC … VS) |
OFF state, switching voltage LOW |
High resistance |
Current-carrying capacity per OSSD |
? 100 mA |
|
Mechanical data
Housing cross-section |
52 mm x 55.5 mm |
Housing material |
Aluminum alloy ALMGSI 0.5 |
Surface treatment |
Powder coated |
Front screen material |
Polycarbonate, scratch-resistant coating |
Ambient data
Enclosure rating |
IP65 (EN 60529) |
Ambient operating temperature |
?30 ?C … +55 ?C |
Storage temperature |
?30 ?C … +70 ?C |
Air humidity |
15 % … 95 %, Non-condensing |
Vibration resistance |
5 g, 10 Hz … 55 Hz (IEC 60068-2-6) |
Shock resistance |
10 g, 16 ms (IEC 60068-2-29) |
Classifications
ECl@ss 5.0 |
27272703 |
ECl@ss 5.1.4 |
27272703 |
ECl@ss 6.0 |
27272703 |
ECl@ss 6.2 |
27272703 |
ECl@ss 7.0 |
27272703 |
ECl@ss 8.0 |
27272703 |
ECl@ss 8.1 |
27272703 |
ECl@ss 9.0 |
27272703 |
ETIM 5.0 |
EC001832 |
ETIM 6.0 |
EC001832 |
UNSPSC 16.0901 |
46171620 |