TIM310-1130000

45,255,000

Tên sản phẩm: 2D LiDAR sensors TiM3xx / TiM31x / Indoor

Danh mục: Detection and ranging solutions

Model: TIM310-1130000

ID: 1056550

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 1056550 Danh mục:

Mô tả sản phẩm

Detection and ranging solutions

Features
Measurement principle HDDM
Application Indoor
Light source Infrared (850 nm)
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
Aperture angle
Horizontal 270?
Scanning frequency 15 Hz
Angular resolution 1?
Working range 0.05 m … 4 m
Scanning range
At 10% remission 2 m
Performance
Response time Typ. 134 ms
Detectable object shape Almost any
Systematic error ? 40 mm 1)
Statistical error 30 mm 1)
Integrated application Field evaluation
Number of field sets 16 field triples (48 fields, 1 triple (3 fields) can be configured directly at the scanner)
Simultaneous evaluation cases 1 (3 fields)
    1) Typical value, actual value depends on environmental conditions.
Interfaces
USB ?
Remark Micro USB
Function AUX, parameterization
Switching inputs 4
Switching outputs 3 (PNP, additional 1 x ?Device Ready?)
Delay time 134 ms … 30,000 ms (configurable)
Dwell time 67 ms … 10,000 ms (configurable)
Optical indicators 2 LEDs (ON, switching status)
Mechanics/electronics
Electrical connection 1 x M12 12-pin male connector (0.8 m)
Supply voltage 9 V DC … 28 V DC
Power consumption Typ. 4 W
Housing color Light blue (RAL 5012)
Enclosure rating IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class III (IEC 61140:2016-1)
Weight 150 g, without connecting cables
Dimensions (L x W x H) 60 mm x 60 mm x 79 mm
Ambient data
Object remission 4 % … > 1,000 % (reflectors)
Electromagnetic compatibility (EMC) IEC 61000-6-3:2006+AMD1:2010 / IEC 61000-6-2:2005
Vibration resistance IEC 60068-2-6:2007
Shock resistance IEC 60068-2-27:2008
Ambient operating temperature ?10 ?C … +50 ?C
Storage temperature ?30 ?C … +70 ?C
Ambient light immunity 80,000 lx
General notes
Note on use The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
Classifications
ECl@ss 5.0 27270990
ECl@ss 5.1.4 27270990
ECl@ss 6.0 27270913
ECl@ss 6.2 27270913
ECl@ss 7.0 27270913
ECl@ss 8.0 27270913
ECl@ss 8.1 27270913
ECl@ss 9.0 27270913
ETIM 5.0 EC002550
ETIM 6.0 EC002550
UNSPSC 16.0901 46171620