Mô tả sản phẩm
Fluid sensors
Medium | Liquid, gaseous |
Pressure type | Gauge pressure |
Measuring range | 0 bar … 0.16 bar |
Process temperature | ?30 ?C … +100 ?C |
Output signal | 0 V … 10 V, 3-wire |
Specialty | Without design specifics |
Non-linearity | ? ? 0.2 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2 |
Accuracy | ? ? 0.5 % of the span |
Non-repeatability | ? ? 0.1 % of the span |
Response time (10 % … 90 %) | ? 1 ms ? 10 ms at medium temperatures below < ?30?C for pressure ranges up to 25 bar or with flush-mounted membrane |
Long-term drift/one-year stability | ? ? 0.2 % of span (at reference conditions) |
Temperature coefficient in rated temperature range | Mean TC of zero: ? 0.2 % of span / 10 K (< 0.4 % for pressure ranges ? 0.25 bar), Mean TC of span ? 0.2 % of span / 10 K |
Rated temperature range | 0 ?C … +80 ?C |
Service life | Minimum 10 Mio. life cycles |
Process connection | G ? female |
Wetted parts | Standard memrane: Stainless steel 1.4571, stainless steel 1.4534 for measuring ranges > 25 bar |
Internal transmission fluid | Synthetic oil (Not available for version with standard membrane for pressure ranges > 25 bar) |
Pressure port | Standard |
Housing material | Stainless steel 1.4571 |
Connection type | Round connector M12 x 1, 4-pin, IP67 |
Supply voltage |
10 V DC … 30 V DC 14 V DC … 30 V DC with output signal 0 V … 10 V |
Electrical safety |
Overvoltage protection: 36 V DC Short-circuit protection: QA towards M Reverse polarity protection: L+ to M Protection class: III |
Dielectric strength | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even in the event of a fault) |
CE-conformity | Pressure equipment directive: 2014/68/EU, EMC directive: 2004/108/EC, EN 61326-2-3 |
Weight sensor | Approx. 200 g |
Seal | Without seal |
Enclosure rating | IP67 |
Protection class III | ? |
Ambient temperature | ?20 ?C … +80 ?C |
Storage temperature | ?40 ?C … +100 ?C, with flush-mounted membrane and cooling element ?20 ?C … +100 ?C |
Shock load |
1000 g according to IEC 60068-2-27 (mechanical shock) 400 g according to IEC 60068-2-27 (mechanical shock) for version with integrated cooling element |
Vibration load |
20 g according to IEC 60068-2-6 (vibration under resonance) 10 g according to IEC 60068-2-6 (vibration undencr resonae) for version with integrated cooling element |
ECl@ss 5.0 | 27200614 |
ECl@ss 5.1.4 | 27200614 |
ECl@ss 6.0 | 27200614 |
ECl@ss 6.2 | 27200614 |
ECl@ss 7.0 | 27200614 |
ECl@ss 8.0 | 27200614 |
ECl@ss 8.1 | 27200614 |
ECl@ss 9.0 | 27200614 |
ETIM 5.0 | EC002476 |
ETIM 6.0 | EC002476 |
UNSPSC 16.0901 | 41112410 |