MOC3ZA-KAZ33A3

16,561,000

Tên sản phẩm: Safety relays Standstill Monitor

Danh mục: sens:Control – safe control solutions

Model: MOC3ZA-KAZ33A3

ID: 6044982

Nhà sản xuất: SICK

Xuất xứ: DE

Hàng mới 100%, bảo hành 12 tháng theo quy định nhà sản xuất

Cung cấp chứng nhận xuất xứ (CO), chứng nhận chất lượng (CQ) theo yêu cầu khách hàng

Mã: 6044982 Danh mục:

Mô tả sản phẩm

sens:Control – safe control solutions

Safety-related parameters
Safety integrity level

SIL3 (IEC 61508)

SILCL3 (EN 62061)

Category Category 4 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 41 x 10-9 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
Stop category 1 (EN 60204-1)
Functions
Drive safety functions Standstill
Interfaces
Connection type Screw-type terminals, plug-in screw-type terminals
Conductor cross-section

Single wire or fine wire (1x): 0.5 mm? … 2.5 mm?

Fine wire with ferrule according to EN 46288 (1x): 0.5 mm? … 2.5 mm?

Encoder interface Motor voltage measuring
Electrical data – Operating data
Supply voltage (A1/A2) 230 V (184 V … 253 V)
Voltage type AC
Residual ripple 10 %
Maximum power consumption ? 6 VA
Supply voltage semiconductor diagnostic outputs (A3/A4) 24 V DC (11 V DC … 30 V DC)
Residual ripple 10 %
Electrical data – Measurement inputs (L1/L2/L3)
Measured/motor voltage ? 690 V AC
For UL 508 applications only ? 600 V AC
Voltage threshold Uan 20 mV … 400 mV, adjustable

Standstill time ts

0.2 s … 6 s, adjustable
Hysteresis (for detection of running motor) 100 %
Response time ? 100 ms
Electrical data – Safety outputs: Normally open contact (13/14, 23/24, 33/34), positively guided N/C contacts: Normally closed contact (41/42)
Contact configuration (safety contacts) 3 contacts NO, 1 contact NC
Contact type Relay, positively guided
Nominal switching voltage 250 V AC
Switching capacity in accordance with AC 15

N/O: 3 A/230 V AC (EN 60947-5-1)

N/C: 2 A/230 V AC (EN 60947-5-1)

Switching capacity in accordance with DC 13 2 A/24 V DC (EN 60947-5-1)
Maximum switching frequency ? 1,200 /h
Contact service life at 230 V / 5 A (AC) cos ? = 0.5 ? 2 x 105 switching operations
Mechanical life ? 50 x 106 switching operations
Electrical data – Diagnostic outputs
Semiconductor APOs (ON, ERR)

Electrically isolated supply via A3/A4

Imax = 100 mA (short-circuit protected)

ON for Release, ERR for Error

Signal contacts 53/54 (normally open contact) 3 A/250 V AC G. P.
Mechanical data
Dimensions (W x H x D) 45 mm x 112 mm x 121 mm
Weight 400 g
Mounting 35 mm mounting rail according to EN 60715
Ambient data
Enclosure rating
Terminals IP20 (EN 60529)
Housing IP40 (EN 60529)
Climate conditions according to 25/060/04 (EN 60068-1)
Vibration resistance 10 Hz … 55 Hz (EN 60068-2-6)
Shock resistance
Single shock 30 g, 11 ms (EN 60068-2-27)
Classifications
ECl@ss 5.0 27371990
ECl@ss 5.1.4 27371990
ECl@ss 6.0 27371819
ECl@ss 6.2 27371819
ECl@ss 7.0 27371819
ECl@ss 8.0 27371819
ECl@ss 8.1 27371819
ECl@ss 9.0 27371819
ETIM 5.0 EC001449
ETIM 6.0 EC001449
UNSPSC 16.0901 41113704