Mô tả sản phẩm
Fluid sensors
Features
Medium | Fluids |
Measurement | Switch, Continuous |
Design | Remote amplifier, length of cable 2 m |
Probe type | Rod probe |
Probe length | 300 mm |
Process pressure | ?1 bar … 10 bar |
Process temperature | ?20 ?C … +100 ?C |
RoHS certificate | ? |
IO-Link | ? |
CULus certificate | ? |
Performance
Accuracy of sensor element | ? 5 mm 1) |
Reproducibility | ? 2 mm |
Resolution | < 2 mm |
Response time | < 400 ms |
Dielectricity constant |
? 5 for rod probe / cable probe ? 1.8 with coaxial tube |
Conductivity | No limitation |
Maximum level change | ? 500 mm/s |
Deactivated area at process connection | 25 mm 2) |
Deactivated area at end of probe | ? 10 mm 1) |
MTTF | 194.3 years (EN ISO 13849-1) |
- 1) With water under reference conditions.2) With parameterized container with water under reference conditions, otherwise 40 mm.
Electronics
Supply voltage | 12 V DC … 30 V DC 1) |
Power consumption | ? 100 mA at 24 V DC without output load |
Initialization time | ? 5 s |
Protection class | III |
Connection type | M12 round connector x 1, 8-pin |
Length of cable | 2 m |
Output signal | 4 mA … 20 mA, 0 V … 10 V automatic switching depending on the load., 1 PNP transistor output (Q1) and 3 PNP/NPN transistor outputs (Q2 to Q4) switchable 1 x PNP + 3 x PNP/NPN + 4 mA … 20 mA / 0 V … 10 V |
Output load | 4 mA … 20 mA < 500 Ohm at Uv > 15 V, 4 mA … 20 mA < 350 Ohm at Uv > 12 V, 0 V … 10 V > 750 Ohm at Uv 14 ? V |
Hysteresis | Min. 2 mm, free adjustable |
Signal voltage HIGH | Vs – 2 V |
Signal voltage LOW | ? 2 V |
Output current | < 100 mA |
Inductive load | < 1 H |
Capacitive load | 100 nF |
Enclosure rating | IP67: EN 60529 |
Temperature drift | < 0.1 mm/K |
Lower signal level | 3.8 mA … 4 mA |
Upper signal level | 20 mA … 20.5 mA |
EMC | EN 61326-2-3, 2014/30/EU |
- 1) All connections are polarity protected. All outputs are overload and short-circuit protected.
Mechanics
Wetted parts | 1.4404, PTFE, FKM |
Process connection | G ? A |
Housing material | Plastic PBT |
Max. probe load | ? 6 Nm |
Length coaxial cable | 2 m |
Ambient data
Ambient operating temperature | ?20 ?C … +60 ?C |
Ambient storage temperature | ?40 ?C … +80 ?C |
Classifications
ECl@ss 5.0 | 27371813 |
ECl@ss 5.1.4 | 27371813 |
ECl@ss 6.0 | 27371813 |
ECl@ss 6.2 | 27371813 |
ECl@ss 7.0 | 27371813 |
ECl@ss 8.0 | 27371813 |
ECl@ss 8.1 | 27371813 |
ECl@ss 9.0 | 27371813 |
ETIM 5.0 | EC001447 |
ETIM 6.0 | EC001447 |
UNSPSC 16.0901 | 41113710 |