Mô tả sản phẩm
Product characteristics |
Output function |
normally open |
Sensing range [mm] |
8 |
Housing |
threaded type |
Dimensions [mm] |
M18 x 1 / L = 80 |
Application |
Installation |
use in hazardous areas only with installed protective cover |
Electrical data |
Operating voltage [V] |
20…250 AC/DC |
Protection class |
II |
Reverse polarity protection |
yes |
Outputs |
Output function |
normally open |
Max. voltage drop switching output DC [V] |
6 |
Max. voltage drop switching output AC [V] |
6.5 |
Minimum load current [mA] |
5 |
Max. leakage current [mA] |
2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC) |
Permanent current rating of switching output AC [mA] |
150 |
Permanent current rating of switching output DC [mA] |
100 |
Short-time current rating of switching output [mA] |
2200; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] |
25 |
Switching frequency DC [Hz] |
50 |
Notes on switching frequency |
only for resistive loads; 2 Hz for utilisation category AC-140 |
|
Short-circuit protection |
no |
Overload protection |
no |
Detection zone |
Sensing range [mm] |
8 |
Real sensing range Sr [mm] |
8 ? 10 % |
Operating distance [mm] |
0…6.48 |
Accuracy / deviations |
Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
Hysteresis [% of Sr] |
1…20 |
Switch point drift [% of Sr] |
-10…10 |
Operating conditions |
Ambient temperature [?C] |
-20…60 |
Protection |
IP 67 |
Tests / approvals |
ATEX marking |
II 3D Ex tc IIIC T80?C Dc X |
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
3 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-6 HF conducted |
3 V |
IEC 60255-5 |
1 kV line to line, Ri: 500 Ohm |
EN 55011 emission |
class B |
|
MTTF [years] |
604 |
Mechanical data |
Weight [g] |
184.5 |
Housing |
threaded type |
Mounting |
non-flush mountable |
Dimensions [mm] |
M18 x 1 / L = 80 |
Thread designation |
M18 x 1 |
Materials |
brass white bronze coated; sensing face: PBT; lock nuts: brass white bronze coated; Protective cover: PA |
Displays / operating elements |
Display |
switching status |
1 x LED, yellow |
|
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ? 2 A; fast acting; Place the fuse outside the hazardous area. |
Accessories |
Accessories (supplied) |
lock nuts: 3 |
Protective cover: 1 |
|
Remarks |
Remarks |
Recommendation: Check the safe functioning of the unit after a short circuit. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Cable: 2 m, PVC; 2 x 0.50 mm? |